Revision of C1567-23 Standard Test Method for Determining the Potential Alkali-Silica Reactivity of Combinations of Cementitious Materials and Aggregate (Accelerated Mortar-Bar Method)

Rationale

When densified silica fume is used in C1567 and mixed as prescribed in the standard, the silica fume agglomerates may not break up. The lack of dispersed silica fume can result in significantly increased expansions of C1567 mortar bars relative to the same mix containing well-dispersed silica fume. Revisions to the standard need to be made to address this issue.

Details

Developed by Subcommittee: C09.50

Committee: C09

Staff Manager: W Scott Orthey

Work Item Status

Date Initiated: 04-30-2024

Technical Contact: Nick Scaglione