Work Item
ASTM WK86049

Revision of E1996-20 Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Windborne Debris in Hurricanes

Rationale

During discussions at the October 2023 E06.22.17 task group about tolerancing the air pressure cycles, it
was agreed to investigate a tolerance on the 0.0 Ppos and 0.0 Pneg requirement after much discussion
that every cycle must meet the minimum and maximum pressure for each cycle. For a system to meet
the minimum of 0.0 psf absolute in the system within the required timeframe, it would be necessary to
put an opposite load (negative during the positive loading, or positive in the negative loading) which
could be more detrimental to the test specimen that the standards intent.
The intent of this revision is not to change the purpose or rigor of the standard but clarify the minimum
requirements to address the intent and add a tolerance to reliably meet the standard. Rather than add
a tolerance to the 0.0P where the pressure is always 0.0, a psf was chosen rather than a tolerance to
simplify the chart.
The 1 psf rating was selected for the task groups discussion. When looking at the tolerances allowed for
air pressure measuring apparatus of +/-2% of maximum rated capacity, or 2 psf, whichever less.

Details

Developed by Subcommittee: E06.51

Committee: E06

Staff Manager: Frank McConnell

Work Item Status

Date Initiated: 04-20-2023

Technical Contact: Lynn Miller

Item: 000

Ballot:

Status: