Work Item
ASTM WK83264

Revision of E1823-21 Standard Terminology Relating to Fatigue and Fracture Testing

Rationale

Item A. Delete applied K-curve
Justification: E647 no longer uses “applied K-curve” nor does any other standard. However, this term is listed under 3.3 Definitions in E1823. E1823 and E647 will be changed to delete this term. This change has been coordinated with Subcommittee E08.06.01 and E08.07.02.

E1823
applied-K curve—a curve (a fixed-force or fixed displacement crack-extension-force curve) obtained from a fracture mechanics analysis for a specific configuration. The curve relates the stress-intensity factor to crack size and either applied force or displacement.
DISCUSSION—The resulting analytical expression is sometimes called a K calibration and is frequently available in handbooks for stress intensity factors. E647

Details

Developed by Subcommittee: E08.02

Committee: E08

Staff Manager: Brian Milewski

Work Item Status

Date Initiated: 08-26-2022

Technical Contact: Charlotte Belsick

Item: 009

Ballot: E08 (22-03)

Status: Negative Votes Need Resolution

Item: 007

Ballot: E08 (22-03)

Status: Negative Votes Need Resolution

Item: 005

Ballot: E08 (22-03)

Status: Negative Votes Need Resolution

Item: 003

Ballot: E08 (22-03)

Status: Negative Votes Need Resolution

Item: 001

Ballot: E08 (22-03)

Status: Negative Votes Need Resolution

Item: 013

Ballot: E08 (22-03)

Status: Negative Votes Need Resolution